Chat with Chief HVAC Engineer
★ Eurovent & AHRI Certified Manufacturer Direct Factory OEM / ODM Customization Global Export to 85+ Countries
WhatsApp: +852 9067 9057 Email: export@huixinhvac.com
🌿 T2 / TB2 Eurovent Thermal Break Casing ⚡ EC Plug Fan with IE5 Motor

High-Efficiency AHU & Commercial HVAC Systems for Global Projects

Custom-engineered Air Handling Units (2,000 to 120,000 m³/h), Hygienic Cleanroom Systems, Heat Recovery Ventilators, and High-Efficiency Chillers built for extreme climates & GMP standards.

50,000+ m²

Smart Factory Facility

85+

Export Destinations

100%

Enthalpy Lab Tested

15-Day

Rapid Lead Time Option

AHU Modular Architecture
Standard Eurovent EN1886 Compliant Series
EUROVENT AHRI 410 CE ISO 9001
Mixing G4+F8 Cooling Heating Recovery EC Fan HEPA
Airflow: 2,000 ~ 120,000 m³/h External Static Pressure: up to 1,200 Pa
Flagship Product Portfolio

Engineered Air Systems & Thermal Machinery

Certified for industrial cleanrooms, luxury commercial complexes, hospitals, and harsh tropical/desert conditions.

Modular Series MODULAR AHU

AERO-M Pro Modular AHU

Double-skin 50mm polyurethane insulated casing with patented thermal break profile. Zero condensation under 90% RH ambient conditions.

Airflow Range:3,000 - 120,000 m³/h
Cooling Capacity:20 - 750 kW
Filtration:G4 + F7 + F9 (HEPA Optional)
Thermal Rating:Eurovent T2 / TB2
Hygienic Cleanroom HYGIENIC DIN1946

MEDIC-AIR Hygienic Cleanroom AHU

Engineered for pharmaceutical GMP Class A/B, hospital operating theaters, and semiconductor fabs. Mirror stainless steel interior, antibacterial coating, zero dead zones.

Standard:DIN 1946-4 / VDI 6022
Filtration Class:H13 / H14 Gel-seal HEPA
Casing Leakage:Class L1 (<0.02 L/s·m²)
Dehumidification:Dewpoint down to -40℃
Energy Recovery ROTARY WHEEL

ECO-RECOV Heat Recovery AHU

Integrated 3A molecular sieve total heat recovery wheel (Sensible + Latent enthalpy efficiency >78%). Drastically cuts chiller/boiler electrical load.

Recovery Efficiency:75% - 84% Enthalpy
Airflow Range:2,000 - 80,000 m³/h
Fan Motor:EC Plug Fan (Modbus)
Energy Savings:Up to 42% kWh reduction
Magnetic Chiller MAG-LEV CHILLER

MAG-LEV Magnetic Bearing Chiller

Oil-free magnetic levitation centrifugal chiller. Ultra-quiet operation (<72 dBA), zero mechanical friction, and IPLV exceeding 10.8 for low operating cost.

Capacity:150 - 1,200 RT (530 - 4220 kW)
Refrigerant:R134a / R1234ze (Low GWP)
COP / IPLV:6.2 / 10.8 (AHRI Standard)
Starting Current:Only 2 Amps (Inverter Soft)
Terminal Unit DC BRUSHLESS FCU

ULTRA-SLIM DC Inverter FCU

Concealed ceiling fan coil unit with stepless brushless DC motor. Ultra-low noise level (down to 21 dB), 30/50/100 Pa external static pressure available.

Airflow:340 - 2,380 m³/h (200 - 1400 CFM)
Cooling Capacity:1.8 - 14.5 kW
Motor Efficiency:BLDC High Efficiency (>80%)
Control:0-10V / Modbus RS485
DX Direct Expansion DX PACKAGED AHU

PACK-DX Rooftop & Custom DX AHU

Standalone direct expansion system paired with inverter condensing units. No chilled water piping required. Ideal for rapid industrial retrofits.

Refrigerant:R410A / R32 Eco-friendly
Compressor:Danfoss / Copeland Inverter Scroll
Airflow:2,500 - 60,000 m³/h
Ambient Range:-15℃ to +52℃ High Ambient
Real-time Engineering Sizing

Online Custom AHU Configurator

Select your design parameters to generate preliminary dimensions, estimated electrical load, and request tailored CAD/BIM drawing files.

Engineering Spec Estimate HX-AHU-250-TB2
Est. Cooling Capacity
152 kW (43 RT)
Est. Fan Motor Power
11.0 kW (EC Plug)
Estimated Unit Dimension (L × W × H)
4,850 × 2,200 × 1,650 mm
Total Unit Operating Weight
Approx. 2,150 kg
✓ Includes G4+F8 filtration, coil heat exchanger, and integrated drain pan. Complies with ISO 14001 and CE directives.
Tailored Industry Solutions

Critical Environments & High-Demand Projects

Proven engineering cases delivering stable temperature, relative humidity, air cleanliness, and acoustic control worldwide.

💊

Pharma & GMP Cleanrooms

Full compliance with FDA/EU-GMP standards. Constant temp & humidity (±0.5℃, ±3% RH), chemical adsorption filtration, and zero-cross-contamination design.

🏥

Hospitals & Isolation Wards

Negative-pressure isolation, laminar airflow operating rooms (Class I), UV germicidal irradiation, and certified HEPA filtration for medical safety.

🖥️

Hyperscale Data Centers

Extreme high-sensible heat ratio CRAH/AHU units, EC electronically commutated fans, free-cooling economizer mode, and dual power backup compatibility.

🏢

Commercial & Mixed-Use Towers

Low noise footprint, integrated total energy recovery wheels, Modbus/BACnet BMS central automation, and low static pressure loss for green building certification (LEED/BREEAM).

Manufacturing & Verification

50,000 m² Intelligent Production & Testing Lab

State-of-the-art CNC salvagnini sheet metal processing, automated foaming lines, and national-certified psychrometric enthalpy difference test laboratories.

1. CNC Laser & Automated Bending

High-precision Salvagnini & Trumpf fiber laser fabrication guarantees ±0.1mm casing accuracy and airtight sealing.

2. High-Pressure PU Injection

45-50 kg/m³ high-density cyclopentane polyurethane foam injection delivers uniform thermal insulation and non-flammable casing.

3. Enthalpy Difference Testing

Full-load simulated airflow, cooling, heating, acoustic noise, and casing leakage tests before crating and export shipping.

4. Global Seaworthy Packaging

Reinforced fumigated solid wood framing, anti-corrosion vacuum film wrapping, and containerized modular splitting for easy site transport.

Direct Factory Pricing

Request an Instant Engineering Quotation

Submit your airflow, static pressure, or project drawings. Our chief HVAC export engineer will respond within 4 business hours.

🔒 We respect your project confidentiality. Non-Disclosure Agreement (NDA) supported upon request.